Sciweavers

ISBI
2007
IEEE

Automated Contour Tracking for Myocardial Elastography In Vivo

13 years 10 months ago
Automated Contour Tracking for Myocardial Elastography In Vivo
Using a high-resolution (30 MHz) ultrasound system (Vevo 770, VisualSonics Inc.) and a retrospective ECGgating technique, an extremely high frame-rate (up to 8 kHz) was previously shown achievable for full-view (12-mm 12-mm) myocardial elastography. In-vivo experiments were performed in anesthetized normal and infarcted mice. In this paper, myocardial contour was manually initialized in the first frame of the ciné-loop and automatically tracked over the entire cardiac cycle, which correctly determined the region of interest (ROI) for better interpretation. The endsystolic cumulative displacement and strain showed that motion and deformation in the infarcted myocardium were significantly reduced, and that the infarcted region underwent thinning, rather than thickening, during systole. In conclusion, high frame rate, full-view myocardial elastography with automated contour tracking could provide regional strain information of the left ventricle throughout an entire cardiac cycle, and c...
Jianwen Luo, Kana Fujikura, Shunichi Homma, Elisa
Added 03 Jun 2010
Updated 03 Jun 2010
Type Conference
Year 2007
Where ISBI
Authors Jianwen Luo, Kana Fujikura, Shunichi Homma, Elisa E. Konofagou
Comments (0)