A Collaborative Approach to In-Place Sensor Calibration

13 years 9 months ago
A Collaborative Approach to In-Place Sensor Calibration
Abstract. Numerous factors contribute to errors in sensor measurements. In order to be useful, any sensor device must be calibrated to adjust its accuracy against the expected measurement scale. In largescale sensor networks, calibration will be an exceptionally difficult task since sensor nodes are often not easily accessible and manual device-bydevice calibration is intractable. In this paper, we present a two-phase post-deployment calibration technique for large-scale, dense sensor deployments. In its first phase, the algorithm derives relative calibration relationships between pairs of co-located sensors, while in the second phase, it maximizes the consistency of the pair-wise calibration functions among groups of sensor nodes. The key idea in the first phase is to use temporal correlation of signals received at neighboring sensors when the signals are highly correlated (i.e. sensors are observing the same phenomenon) to derive the function relating their bias in amplitude. We fo...
Vladimir Bychkovskiy, Seapahn Megerian, Deborah Es
Added 07 Jul 2010
Updated 07 Jul 2010
Type Conference
Year 2003
Where IPSN
Authors Vladimir Bychkovskiy, Seapahn Megerian, Deborah Estrin, Miodrag Potkonjak
Comments (0)