Sciweavers

PERVASIVE
2008
Springer

Detecting Human Movement by Differential Air Pressure Sensing in HVAC System Ductwork: An Exploration in Infrastructure Mediated

13 years 4 months ago
Detecting Human Movement by Differential Air Pressure Sensing in HVAC System Ductwork: An Exploration in Infrastructure Mediated
We have developed an approach for whole-house gross movement and room transition detection through sensing at only one point in the home. We consider this system to be one member of an important new class of human activity monitoring approaches based on what we call infrastructure mediated sensing, or "home bus snooping." Our solution leverages the existing ductwork infrastructure of central heating, ventilation, and air conditioning (HVAC) systems found in many homes. Disruptions in airflow, caused by human interroom movement, result in static pressure changes in the HVAC air handler unit. This is particularly apparent for room-to-room transitions and door open/close events involving full or partial blockage of doorways and thresholds. We detect and record this pressure variation from sensors mounted on the air filter and classify where certain movement events are occurring in the house, such as an adult walking through a particular doorway or the opening and closing of a pa...
Shwetak N. Patel, Matthew S. Reynolds, Gregory D.
Added 14 Dec 2010
Updated 14 Dec 2010
Type Journal
Year 2008
Where PERVASIVE
Authors Shwetak N. Patel, Matthew S. Reynolds, Gregory D. Abowd
Comments (0)