Sciweavers

ICCAD
2005
IEEE

Global signaling over lossy transmission lines

14 years 1 months ago
Global signaling over lossy transmission lines
We describe an interconnect scheme based on lossy transmission lines, compare this scheme with traditional bus based links, and present performance data. Unlike some other schemes there is no requirement for upconversion, equalization, or special metal processing. In preliminary work, we have measured data rates of 14 Gbps (limited by test equipment) over a 7.2 mm interconnection, implemented in 0.18 µm CMOS. For active links signaling over a single serial link, is more power efficient than over traditional parallel buses, does not require repeaters and is less affected by noise and coupling.
Michael P. Flynn, Joshua Jaeyoung Kang
Added 16 Mar 2010
Updated 16 Mar 2010
Type Conference
Year 2005
Where ICCAD
Authors Michael P. Flynn, Joshua Jaeyoung Kang
Comments (0)