Sciweavers

ISBI
2008
IEEE
14 years 5 months ago
Medial-based Bayesian tracking for vascular segmentation: Application to coronary arteries in 3D CT angiography
We propose a new Bayesian, stochastic tracking algorithm for the segmentation of blood vessels from 3D medical image data. Inspired by the recent developments in particle filterin...
David Lesage, Elsa D. Angelini, Isabelle Bloch, Ga...
ISBI
2008
IEEE
14 years 5 months ago
Double time-scale image reconstruction of the beating and developing embryonic zebrafish heart
We present a time-lapse collection and reconstruction technique that allows following embryonic heart development at any computationally halted heart contraction state. The centra...
Michael Liebling, Julien Vermot, Scott E. Fraser
ISBI
2008
IEEE
14 years 5 months ago
Distributed online anomaly detection in high-content screening
This paper presents an automated, online approach to anomaly detection in high-content screening assays for pharmaceutical research. Online detection of anomalies is attractive be...
Adam Goode, Rahul Sukthankar, Lily B. Mummert, Mei...
ISBI
2008
IEEE
14 years 5 months ago
Automated proteome-wide determination of subcellular location using high throughput microscopy
A major source of information for identifying subcellular location on a proteome-wide basis will be imaging of tagged proteins in living cells using fluorescence microscopy. We ha...
Robert F. Murphy
ISBI
2008
IEEE
14 years 5 months ago
Axonal bouton modeling, detection and distribution analysis for the study of neural circuit organization and plasticity
We propose a novel method for axonal bouton modeling and automated detection in populations of labeled neurons, as well as bouton distribution analysis for the study of neural cir...
Abhay Mavalankar, Amina Chebira, Christina A. Hall...
ISBI
2008
IEEE
14 years 5 months ago
Local quality assessment for optical coherence tomography
Optical Coherence Tomography (OCT) is a non-invasive tool for visualizing the retina. It is increasingly used to diagnose eye diseases such as glaucoma and diabetic maculopathy. H...
Gadi Wollstein, Hiroshi Ishikawa 0002, Joel Schuma...
ISBI
2008
IEEE
14 years 5 months ago
Fast displacement probability profile approximation from HARDI using 4th-order tensors
Cartesian tensor basis have been widely used to approximate spherical functions. In Medical Imaging, tensors of various orders have been used to model the diffusivity function in ...
Angelos Barmpoutis, Baba C. Vemuri, John R. Forder
ISBI
2008
IEEE
14 years 5 months ago
Can voronoi diagram model cell geometries in early sea-urchin embryogenesis?
We test the hypothesis that cell membranes in early seaurchin embryos can be modeled as a Voronoi diagram from nuclei centers. In order to obtain a model of the cell geometry agai...
Andrés Santos, Benoit Lombardot, Carlos Cas...
ISBI
2008
IEEE
14 years 5 months ago
Deconvolution of 3D fluorescence micrographs with automatic risk minimization
We investigate the problem of automatic tuning of a deconvolution algorithm for three-dimensional (3D) fluorescence microscopy; specifically, the selection of the regularization p...
Sathish Ramani, Cédric Vonesch, Michael Uns...
ISBI
2008
IEEE
14 years 5 months ago
Tracking displacements of intracellular organelles in response to nanomechanical forces
The living cell is under constant influence of mechanical forces from its environment. These forces affect many aspects of the cell's behaviour, including morphology, growth,...
Yaron R. Silberberg, Andrew E. Pelling, Gleb E. Ya...