Variance Reduction in Monte Carlo Capacitance Extraction

14 years 4 months ago
Variance Reduction in Monte Carlo Capacitance Extraction
In this article we address efficiency issues in implementation of Monte Carlo algorithm for 3D capacitance extraction. Error bounds in statistical capacitance estimation are discussed. Methods to tighten them through variance reduction techniques are detailed. Sample values in implementation of Monte Carlo algorithm is completely determined by the first hop in random walk. This in turn facilitates application of variance reduction techniques like importance sampling and stratified sampling to be used effectively. Experimental results indicate average speedup of 16X in simple uniform dielectric technologies, 7.3X in technologies with layers of dielectrics and 4.6X in technologies having conformal dielectrics.
Shabbir H. Batterywala, Madhav P. Desai
Added 01 Dec 2009
Updated 01 Dec 2009
Type Conference
Year 2005
Where VLSID
Authors Shabbir H. Batterywala, Madhav P. Desai
Comments (0)